NOVA 600 M-A SV
GENERAL DATA
Applications
The submersible pump from the NOVA series is designed mainly for automatically operated fixed applications in domestic use, draining basements and garages which are subject to flooding.
Thanks to its compact, easy to handle form, it may also be used as a portable pump for emergencies such as lifting water from tanks or rivers, emptying swimming pools, fountains, excavations and underpasses. It is also ideal for gardening and hobbies in general.
Version with special stainless steel pump shaft also available (SV).
Constructional features of the pump
Hydro resistant technopolymer pump body, cover, and suction grid.
Stainless steel motor, rotor shaft and screws.
Threefold seal with interposed rings with oil pre-chamber.
Constructional features of the motor
Submersible type continuous duty asynchronous motor.
Stator enclosed in airtight stainless steel casing, with an outer cover that protects the wiring and the capacitor.
Rotor running on permanently lubricated ball bearings, oversized to ensure low noise and durability.
Standard built-in thermo-amperometric protection. Capacitor permanently fitted on single phase versions.
For the protection of the three-phase motor, we recommend the use of remote overload cut-outs, in compliance with local regulations.
Construction according to CEI 2-3 and CEI 61-69 (EN 60335-2-41).
Standard voltage: single-phase 220-240 V / 50 Hz, three-phase 400 V / 50 Hz
Standard cables for the single-phase version:
5 metres H05RN-F: NOVA 180 M-A - NOVA 300 M-A - NOVA 600 M-A
10 metres H05RN-F: NOVA 180 M-NA - NOVA 200 M-NA
10 metres H07RN-F: NOVA 600 M-NA
Standard plug for the single-phase version: SCHUKO CEE 7 - VII - UNEL 47166-68
Standard cables for the three-phase version: 5 metres H07 RN-F
TECHNICAL DATA
- Operating range: from 1 to 16 m3/h with head up to 10,2 metres
- Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)
- Pumped liquid: dirty water without fibres.
- Free passage of solids through the suction grid: 10 mm
- Minimum suction depth:
NOVA 180: 77 mm
NOVA 200 - NOVA 180 NA: 8 mm
NOVA 300: 85 mm
NOVA 600 A:175 mm
NOVA 600 NA: 38 mm
- Maximum immersion depth: 7 metres
- Maximum dry running time: 1 minute
- Motor protection: IP68
- Insulation class: F
- Installation: fixed or portable in a vertical position