Product description
Manually operated gauge push-button stop cock for temporary application of pressure to a pressure gauge.
Parameter
Operating overpressure for medium gas Max. 5 bar
Operating temperature 0 °C to 70 °C
Ambient temperature -20 °C to 60 °C
Connection Rp ½
Direction of flow Marked by arrow
Tightness class Class 1
Mounting and commissioning
Any installation position possible.
- Tightly screw the push-button stop cock to a T piece of the gas supply. Pay attention to the direction of
flow!
- Tightly screw in the gauge.
Operation
- When the spring-suspended push button piston is pushed all the way down, the way for the system pressure to the gauge is opened and the pressure can be indicated.
- When you release the push button, the spring moves it back to the initial position. This interrupts the system pressure to the gauge and relieves the gauge at the same time.